Cisco 7604 + RSP720 3CXL + WS-X6704-10GE는 포트의 오류 카운터를 증가 시키지만 포트를 통한 손실은 없습니다


10

Cisco 7604 + RSP720 3CXL + WS-X6704-10GE는 포트의 오류 카운터를 증가 시키지만 포트를 통한 손실은 없습니다.

   #sh interfaces Te3/4
  TenGigabitEthernet3/4 is up, line protocol is up (connected)
  Hardware is C7600 10Gb 802.3, address is 588d.09b4.8d80 (bia 588d.09b4.8d80)
  MTU 1500 bytes, BW 10000000 Kbit/sec, DLY 10 usec,
     reliability 255/255, txload 42/255, rxload 42/255
  Encapsulation 802.1Q Virtual LAN, Vlan ID  1., loopback not set
  Keepalive set (10 sec)
  Full-duplex, 10Gb/s
  Transport mode LAN (10GBASE-R, 10.3125Gb/s)
  input flow-control is off, output flow-control is off
  Clock mode is auto
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters 3d03h
  Input queue: 0/75/291/291 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 1667291000 bits/sec, 244099 packets/sec
  5 minute output rate 1665910000 bits/sec, 243961 packets/sec
  L2 Switched: ucast: 4875 pkt, 1667250 bytes - mcast: 0 pkt, 0 bytes
  L3 in Switched: ucast: 0 pkt, 0 bytes - mcast: 0 pkt, 0 bytes mcast
  L3 out Switched: ucast: 0 pkt, 0 bytes mcast: 0 pkt, 0 bytes
     46982598919 packets input, 40800999530943 bytes, 0 no buffer
     Received 1748682 broadcasts (0 IP multicasts)
     0 runts, 0 giants, 0 throttles
     155706 input errors, 65000 CRC, 11401 frame, 0 overrun, 0 ignored
     0 watchdog, 0 multicast, 0 pause input
     0 input packets with dribble condition detected
     46985469520 packets output, 40792363160570 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 unknown protocol drops
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier, 0 pause output
     0 output buffer failures, 0 output buffers swapped out

라우터는 Policing을 사용하여 고객 및 채널 제한을 종료하는 데 사용됩니다.

최신 정보:

#sh int te3/4 transceiver detail
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.

                              High Alarm  High Warn  Low Warn   Low Alarm
           Temperature        Threshold   Threshold  Threshold  Threshold
Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4        28.2                   70.0       60.0        5.0        0.0

                              High Alarm  High Warn  Low Warn   Low Alarm
           Voltage            Threshold   Threshold  Threshold  Threshold
Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4        0.00                    N/A        N/A        N/A        N/A

                              High Alarm  High Warn  Low Warn   Low Alarm
           Current            Threshold   Threshold  Threshold  Threshold
Port       (milliamperes)     (mA)        (mA)       (mA)       (mA)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A                    N/A        N/A        N/A        N/A

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Transmit Power     Threshold   Threshold  Threshold  Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A         ++         0.9        0.4       -8.2       -8.1

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Receive Power      Threshold   Threshold  Threshold  Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A         ++         0.9        0.4      -14.4      -15.0

"XENPACK to SFP +"및 "Direct Attach Cable SFP + to SFP +"어댑터를 사용하고 있습니다. 이는 진단을 복잡하게합니다.

성장 카운터의 원인을 어디에서 찾을 수 있습니까?


1
광섬유 신호 강도, 깨끗한 광섬유 종단 (패치 패널 포함)을 확인하고 광학 장치를 교체하십시오.
Mike Pennington

어댑터 "XFP to SFP +"와 함께 직접 연결 케이블 "SFP + to SFP +"를 사용하고 있습니다. 무리에서 무언가를 교체해야 할 수도 있습니다.
Allan Sundry

실례합니다. 어댑터 "XENPACK to SFP +"및 "직접 연결 케이블 SFP + to SFP +"
Allan Sundry

@AllanSundry 변명!
jwbensley 2013 년

답변:


4

CRC 및 프레이밍 오류 및 일반 입력 오류가 표시됩니다. 포트를 설정하는 동안이 문제가 발생하면 사람들이 여전히 광섬유를 사용하여 발생할 수 있습니다.

대부분의 경우 정상 작동 중에이 현상이 발생하면 조명 수준이 낮거나 광섬유 또는 광학 장치에 다른 오류가 있음을 나타냅니다.

당신은 조명 수준을 확인할 수 있습니다

show interfaces transceiver 

타사 광학 장치에 대한 잘못된 판독 값을보고 할 수 있습니다. 그런 다음 사양의 범위 내에 있는지 확인하려면 광학 장치의 전원 예산 / 제한을 찾아야합니다.

Mike가 제안한대로 모든 광섬유 종단을 청소하십시오. 그래도 광학 장치 교체를 시도해도 도움이되지 않습니다.

현재 오류가 너무 작아서 눈에 띄지 않지만 매우 빠르게 변경 될 수 있습니다. 라인에서 갑자기 더 많은 손실이 있기 때문에 오전 3시에 깨어 난 것보다 지금 수정하는 것이 좋습니다.

또한 인터페이스 (오류) 카운터의 경우 Cisco 출력 인터프리터를 사용하여 현재보고있는 내용을 분석하는 경우가 있습니다.

https://www.cisco.com/pcgi-bin/Support/OutputInterpreter/home.pl

소금 알갱이로 분석을 수행하십시오. 때로는 요점이 빠져 있지만 잘못된 점을 빨리 볼 수 있습니다.

업데이트 :

XENPAK / SFP + 어댑터 및 DAC 케이블을 사용하는 경우 두 케이블 중 하나에 문제가있을 수 있습니다. 어댑터 및 / 또는 케이블을 교체하십시오. DAC에는 광학 장치가 없으므로 (구리) interface transceiver명령에는 유용한 정보가 표시되지 않습니다.

또한 케이블 길이와 전자기 간섭으로 인해 DAC에 문제가 발생할 수 있습니다. 모든 것이 실패하면 광학 및 광 케이블로 전환하여 도움이되는지 확인하십시오.


"출력 통역사는 Cisco 서비스 계약을 체결 한 등록 된 Cisco.com 사용자에게만 제공됩니다." pdf 형식의 기사를 제공해 주시겠습니까?
Allan Sundry

.plSebastian이 링크 한 CGI 인 Allan 에는 PDF 사본이 없습니다. 그것은 show 명령 출력을 붙여 넣고 잠재적 인 치료법에 대한 권장 사항을 얻을 수있는 도구입니다.
Mike Pennington

불행히도이 페이지에 액세스 할 수 없습니다. 어댑터 "XENPACK to SFP +"및 "직접 연결 케이블 SFP +-SFP +"을 사용하면 "sh int te3 / 4 송수신기 세부 사항"(첫 번째 포스트에 추가됨) 명령이 비어 있습니다.
Allan Sundry

좋아, 나는 대답을 업데이트했다.
Sebastian Wiesinger

DAC를 광 링크 오류 카운터로 교체 한 후 약 8 시간 동안 약 2 개의 입력 오류가 증가하지 않았습니다.
Allan Sundry

9

손실이 있습니다. 당신은 그 영향을보고 있지 않습니다. 이전 3 일 4 시간 동안 46982598919 패킷 중 155706 개의 입력 오류 만 표시됩니다. 이는 .0003 %의 패킷 손실이므로 테스트 중에 직접 확인하기가 어렵습니다.

운영상의 영향이 없다면 안전하게 무시할 수 있습니다. 이러한 낮은 수준의 패킷 손실은 표준 IP 네트워크에서 무시할 수있는 영향을 미치므로 상위 계층 프로토콜이 그에 따라 조정됩니다.

소스를 추적하려는 경우 어려울 수 있습니다. Mike가 지적했듯이 첫 번째 단계는 신호 강도를 확인하고 (인터페이스 xxxx 송수신기 표시, DOM 기능이있는 모듈이 필요함) 패치 코드의 종단점을 청소하는 것입니다. 그래도 문제가 해결되지 않으면 패치 코드를 교체하십시오. 최종 짚으로 실제 광학 모듈을 교체하십시오.